Stack testing is our specialty. We have been growing and developing with the industry for nearly 40 years. When you need accurate, timely data, Ektimo delivers.
Whatever your industry; energy, mining, manufacturing or processing, Ektimo can service your stack testing and other emissions testing needs.
"Dependable, Versatile, Innovative"
We have the capacity to design testing equipment to suit the particular location.
Each project is assigned a Project Manager who is technically qualified and highly competent in emission testing. The Project Manager discusses your project needs, prepares quotations, schedules testing, handles all pre and post-test communications, coordinates the work of the test team and laboratory, and oversees the reporting effort.
“Clients always have direct and immediate access to the person responsible for their project, which enables us to consistently meet scheduling requirements and report deadlines.”
Ektimo normally carries out on-site assessment visits prior to monitoring. This enables checking for safe access and the adequate location of the sampling points. It is also important to ensure that monitoring work is scheduled for times when normal work, or production is under way.
Ektimo is accredited with the National Association of Testing Authorities (NATA) for an extensive range of air emission testing methods, including the industry standard AS, USEPA and ISO methods.
|
AS 3543, AS4323.2, USEPA 5,USEPA 5B, USEPA 9, USEPA 17, USEPA 201A, USEPA 202, ISO 9096, NSW EPA OM-5, NSW EPA OM-9, NSW EPA TM-15, NSW TM-16, SA EPA 03.01, USEPA CTM 040, VDI 2066 |
|
ISO 7935, ISO 10849, ISO 632, ISO 12039, NSW EPA TM-4, NSW EPA TM-11, NSW EPA TM-24, NSW EPA TM-25, NSW EPA TM-32, NSW OM-1, SA EPA 03.08, SA EPA 03.12, SA EPA 03.14, USEPA OTM 13, USEPA 3, USEPA 3A, USEPA 6, USEPA 6C, USEPA 7D, USEPA 7E, USEPA 10, USEPA 20, VIC EPA 3161, In-house methods |
|
In-house methods |
|
USEPA 11, USEPA 15, USEPA 16, USEPA16A, NSW TM-5, NSW TM-33, Vic EPA B18, In-house methods |
|
USEPA 8, ISO 7934, NSW EPA TM-3, SA EPA 03.02, VIC EPA 3171, In-house methods |
|
USEPA 18, USEPA 106, USEPA 308, USEPA SW-846 0030,USEPA SW-846 0031, USEPA SW-846 8260, , Vic EPA 4230, In-house methods |
|
USEPA 25A, NSW TM-34 |
|
USEPA 23, USEPA SW-846 0010, USEPA SW-846 0023A, NSW EPA TM-18, NSW EPA OM-6, CARB 429, ISO 11338-1, ISO 11338-2 |
|
USEPA 316, USEPA SW-846 0011, In-house methods |
|
USEPA CTM 32, In-house methods |
|
Vic EPA 4210, In-house methods |
|
In-house methods |
|
USEPA 13A, USEPA 13B, USEPA 26, USEPA 26A, NSW EPA TM-7, NSW EPA TM-8, NSW EPA TM-9, Vic EPA 3140, Vic EPA 3141, Vic EPA 3142, SA EPA 03.03, In-house methods |
|
In-house methods |
|
USEPA CTM027, In-house methods |
|
USEPA CTM033, In-house methods |
|
ASTM D6784-02, USEPA 29, CARB 425, USEPA 306, USEPA SW-846 0061, NSW EPA TM-12, NSW EPA TM-13, NSW EPA TM-14, NSW EPA OM-3, NSW EPA OM-4, SA 03.07, In-house methods |
|
AS4323.3, AS4323.4, NSW EPA OM-7, NSW EPA OM-8, In-house methods |
|
USEPA PS 2, USEPA PS 3, USEPA PS 4, USEPA PS 4A, USEPA PS 5, USEPA PS 6, USEPA PS 7, USEPA PS 8A, USEPA PS 11, |

